Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 5 de 5
Filter
2.
ABCD (São Paulo, Online) ; 35: e1647, 2022. tab
Article in English | LILACS-Express | LILACS | ID: biblio-1383221

ABSTRACT

ABSTRACT - BACKGROUND: Colorectal cancer generally metastasizes to the liver. Surgical resection of liver metastasis, which is associated with systemic chemotherapy, is potentially curative, but many patients will present recurrence. In selected patients, repeated hepatectomy is feasible and improves overall survival. AIM: This study aimed to analyze patients with colorectal liver metastasis (CRLM) submitted to hepatectomy in three centers from Rio de Janeiro, over the past 10 years, by comparing the morbidity of first hepatectomy and re-hepatectomy. METHODS: From June 2009 to July 2020, 192 patients with CRLM underwent liver resection with curative intent in three hospitals from Rio de Janeiro Federal Health System. The data from patients, surgeries, and outcomes were collected from a prospectively maintained database. Patients submitted to first and re-hepatectomies were classified as Group 1 and Group 2, respectively. Data from groups were compared and value of p<0.05 was considered significant. RESULTS: Among 192 patients, 16 were excluded. Of the remaining 176 patients, 148 were included in Group 1 and 28 were included in Group 2. Fifty-five (37.2%) patients in Group 1 and 13 (46.5%) in Group 2 presented postoperative complications. Comparing Groups 1 and 2, we found no statistical difference between the cases of postoperative complications (p=0.834), number of minor (p=0.266) or major (p=0.695) complications, and deaths (p=0.407). CONCLUSIONS: No differences were recorded in morbidity or mortality between patients submitted to first and re-hepatectomies for CRLM, which reinforces that re-hepatectomy can be performed with outcomes comparable to first hepatectomy.


RESUMO - RACIONAL: O câncer colorretal geralmente metastatiza para o fígado. Hepatectomia associada à quimioterapia sistêmica é potencialmente curativa para metástases hepáticas colorretais, entretanto, muitos pacientes apresentarão recidiva após a cirurgia. Em casos selecionados, a re-hepatectomia é viável, com relatos de melhora na sobrevida global. OBJETIVO: Analisar pacientes com metástase hepática colorretal operados em três centros do Rio de Janeiro, nos últimos 10 anos, comparando as morbidades da primeira hepatectomia e da re-hepectomia. MÉTODOS: De junho de 2009 a julho de 2020, 192 pacientes com metástase hepática colorretal foram submetidos à hepatectomia em três hospitais do Rio de Janeiro. Os dados dos pacientes, cirurgias e desfechos foram coletados de um banco de dados mantido prospectivamente. Pacientes submetidos à primeira hepatectomia e re-hepatectomia foram classificados como Grupo 1 e Grupo 2, respectivamente. Os dados dos grupos foram comparados e o valor de p<0,05 foi considerado significativo. RESULTADOS: Dentre 192 pacientes, dezesseis foram excluídos. Dos 176 pacientes restantes, 148 e 28 foram incluídos dos Grupos 1 e 2, respectivamente. Cinquenta e cinco (37,2%) pacientes no Grupo 1 e treze (46,5%) no Grupo 2 apresentaram complicações pós-operatórias. Comparando os Grupos 1 e 2, não foi observada diferença estatística entre o número de pacientes com complicações pós-operatórias (p = 0,834), complicações menores (p = 0,266) ou maiores (p = 0,695) e óbitos (p = 0,407). CONCLUSÕES: Não foram registradas diferenças na morbidade ou mortalidade entre os pacientes submetidos à primeira ou à re-hepatectomia em pacientes com metástase hepática colorretal, o que sustenta que a re-hepatectomia pode ser realizada com resultados comparáveis à primeira hepatectomia.

3.
ABCD (São Paulo, Impr.) ; 33(4): e1555, 2020. graf
Article in English | LILACS | ID: biblio-1152633

ABSTRACT

ABSTRACT Background: Laparoscopic liver resection is performed worldwide. Hemorrhage is a major complication and bleeding control during hepatotomy is an important concern. Pringle maneuver remains the standard inflow occlusion technique. Aim: Describe an extracorporeal, efficient, fast, cheap and reproducible way to execute the Pringle maneuver in laparoscopic surgery, using a chest tube. Methods: From January 2014 to March 2020, our team performed 398 hepatectomies, 63 by laparoscopy. We systematically encircle the hepatoduodenal ligament and prepare a tourniquet to perform Pringle maneuver. In laparoscopy, we use a 24 Fr chest tube, which is inserted in the abdominal cavity through a small incision. We thread the cotton tape through the tube, pulling it out through the external end, outside the abdomen. To perform the tourniquet, we just need to push the tube as we hold the tape, clamping both with one forceps. Results: The 24 Fr chest tube is firm and works perfectly to occlude blood inflow as the cotton band is tightened. It has an internal diameter of 5,5 mm, sufficient for a laparoscopic grasper pass through it to catch the cotton band, and an external diameter of 8 mm, which allows to be inserted in the abdomen through a tiny incision. The cost of this tube and the cotton band is less than US$ 1. No complications related to the method were identified in our patients. Conclusions: The extracorporeal Pringle maneuver presented here is a safe, cheap and reproducible method, that can be used for bleeding control in laparoscopic liver surgery.


RESUMO Racional: Ressecções hepáticas laparoscópicas são realizadas em todo mundo. A hemorragia é complicação grave e o controle do sangramento durante a hepatotomia é preocupação importante. A manobra de Pringle continua sendo a técnica padrão de oclusão do influxo sanguíneo. Objetivo: Descrever uma maneira eficiente, rápida, barata e reproduzível de executar a manobra de Pringle extracorpórea, em operação laparoscópica, utilizando um dreno de tórax. Métodos: De janeiro/2014 a março/2020, realizamos 398 hepatectomias, 63 por laparoscopia. Nós sistematicamente laçamos o ligamento hepatoduodenal e preparamos um torniquete para a manobra de Pringle. Na laparoscopia, usamos um dreno de tórax 24 Fr, inserido na cavidade abdominal através de uma pequena incisão. Passamos a fita de algodão através do tubo, puxando-a pela extremidade externa, fora do abdome. Para apertar o torniquete, basta pressionar o tubo enquanto seguramos a fita, prendendo ambos com uma pinça. Resultados: O dreno de tórax 24 Fr é firme e funciona perfeitamente para ocluir influxo de sangue, à medida que apertamos o torniquete. Tem diâmetro interno de 5,5 mm, suficiente para passar uma pinça laparoscópica e puxar a fita de algodão, e um diâmetro externo de 8 mm, permitindo a inserção no abdome através de uma pequena incisão. O custo do tubo e fita é inferior a US$ 1, valor insignificante. Não foram identificadas complicações relacionadas ao método em nossos pacientes. Conclusões: A manobra extracorpórea de Pringle apresentada aqui é método seguro, barato e reproduzível, que pode ser utilizado para o controle do sangramento em hepatectomias laparoscópicas.


Subject(s)
Humans , Laparoscopy/methods , Abdominal Cavity/diagnostic imaging , Hepatectomy/methods , Liver Neoplasms/surgery , Constriction
4.
ABCD (São Paulo, Impr.) ; 27(3): 204-205, Jul-Sep/2014. graf
Article in English | LILACS | ID: lil-720393

ABSTRACT

BACKGROUND: Portal vein embolization is an accepted procedure that provides hypertrophy of the future remnant liver in order to reduce post-hepatectomy complications. AIM: To present a series submitted to portal vein embolization using an adapted hysterosalpingography catheter via transileocolic route. METHODS: Were performed right portal branch embolization in 19 patients using hysterosalpingography catheter. For embolizing the vessel, was used Gelfoam(r) powder with absolute alcohol solution. Indications for hepatectomy were colorectal liver metastases in all cases. RESULTS: An adequate growth of the future remnant liver was achieved in 15 patients (78.9%) and second time hepatectomy could be done in 14 (73.7%). In one patient (5.2%), tumor progression prevented surgery. One patient presented acute renal failure after portal embolization. CONCLUSIONS: The hysterosalpingography catheter is easy to handle and can be introduced into the portal vein with a wire guide. There were no major post-embolization complication. Its use is safe, cheap and effective. .


RACIONAL: Embolização da veia porta é procedimento consagrado para estimular a hipertrofia do fígado remanescente, a fim de reduzir as complicações pós-hepatectomia. OBJETIVO: Apresentar série de casos submetidos à embolização da veia porta usando cateter adaptado de histerossalpingografia, por via transileocólica. MÉTODOS: Foi realizada embolização do ramo portal direito em 19 pacientes utilizando cateter de histerossalpingografia. Foi usado Gelfoam(r) em pó com solução de álcool absoluto, como material embolizante. As indicações para hepatectomia foram metástases hepáticas colorretais em todos os casos. RESULTADOS: Hipertrofia adequada do fígado remanescente foi alcançada em 15 pacientes (78,9%) e a hepatectomia foi realizada em 14 (73,7 %). Em um (5,2 %), a progressão do tumor impediu a realização da operação. Um paciente apresentou insuficiência renal aguda após embolização portal. CONCLUSÕES: O cateter de histerossalpingografia é fácil de ser manuseado e pode ser introduzido na veia porta com um fio guia. Não houve complicação grave pós-embolização. Seu uso é seguro, barato e eficaz. .


Subject(s)
Humans , Embolization, Therapeutic/instrumentation , Hepatectomy , Portal Vein , Catheters , Embolization, Therapeutic/methods , Equipment Design , Hysterosalpingography/instrumentation
5.
Acta cir. bras ; 23(1): 48-54, Jan.-Feb. 2008. graf
Article in English | LILACS | ID: lil-474140

ABSTRACT

PURPOSE: To asses the dissemination of bacteria labeled with technetium-99m (99mTc) from peritoneal cavity after different surgical procedures. METHODS: Bacteria of the Escherichia coli species labeled with 99mTc were used in a concentration of 10(8) units of colony-makers for ml (UFC/ml) and 1ml was inoculated through intra-peritoneal via. Forty-eight rats were divided into four groups: control, laparotomy, pneumoperitoneum with 10mmHg and pneumoperitoneum with 20mmHg of CO2. Procedures were performed 20 min after injection of the inoculum and lasted 30 min. Animals were sacrificed after six hours (Group 1) and 24 hours (Group 2). Samples of blood, liver and spleen were collected for radioactivity counting. RESULTS: After six hours, indirect detection of the bacteria in different organs was uniform in all groups. After 24 hours, a larger detection of technetium was observed in the livers of animals of the group insufflated with 20mmHg of CO2, when compared with those of control group (p<0.01). The other groups did not present statistically significant variations. CONCLUSIONS: The use of a higher intra-abdominal pressure was associated with a higher bacterial dissemination to the liver. The application of lower intra-abdominal pressures may be associated with a lower dissemination of the infectious status during laparoscopic approach of peritonitis status.


OBJETIVO: Avaliar a disseminação de bactérias marcadas com tecnécio-99m (99mTc) a partir da cavidade peritoneal após diferentes procedimentos cirúrgicos. MÉTODOS: Foram utilizadas bactérias da espécie Escherichia coli marcadas com 99mTc em uma concentração de10(8) unidades formadoras de colônia por ml (UFC/ml) sendo inoculado 1ml por via intra-peritoneal. Quarenta e oito ratos foram divididos em quatro grupos: controle, laparotomia, pneumoperitôneo com 10 mmHg e pneumoperitôneo com 20 mmHg de CO2. Os procedimentos foram realizados 20 minutos após a injeção do inóculo e duraram 30 minutos. Os animais foram sacrificados após seis horas (grupo 1) e 24 horas (grupo 2). Foram coletadas amostras de sangue, fígado e baço para contagem radioativa. RESULTADOS: Após seis horas, a detecção indireta das bactérias nos diferentes órgãos foi uniforme em todos os grupos. Após 24 horas, observou-se uma maior detecção de tecnécio nos fígados dos animais do grupo insuflado com 20 mmHg de CO2, quando comparados aos do grupo controle (p<0,01). Os outros grupos não apresentaram variações estatisticamente significativas. CONCLUSÕES: A utilização de pressões intra-abdominais mais elevadas associou-se a uma maior disseminação bacteriana para o fígado. A utilização de pressões intra-abdominais menos elevadas na abordagem da peritonite pode estar associada a uma menor disseminação do quadro infeccioso.


Subject(s)
Animals , Male , Rats , Escherichia coli Infections , Escherichia coli/growth & development , Peritonitis/surgery , Pneumoperitoneum, Artificial/adverse effects , Sepsis , Colony Count, Microbial , Disease Models, Animal , Escherichia coli Infections/microbiology , Escherichia coli/drug effects , Insufflation/adverse effects , Laparoscopy/adverse effects , Laparotomy/adverse effects , Liver/microbiology , Liver/radiation effects , Peritoneal Cavity/microbiology , Peritonitis/microbiology , Peritonitis , Pneumoperitoneum, Artificial/methods , Rats, Wistar , Sepsis/microbiology , Spleen/microbiology , Spleen/radiation effects , Technetium
SELECTION OF CITATIONS
SEARCH DETAIL